KAYE RF valprobe II Loggers

    Tags: , , , , , .

    Deskripsi produk:

    Feature  and specification for Kaye RF valprobe II Loggers:

    • RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
    • Provides 100% data redundancy in both remote logger and base station in addition highly reliable RF network
    • New State of Art Industrial design with integrated LCD Display
    • Dual powered, logger runs on AC Power and/or Battery. Battery life greater than 1 year in typical use, using Standard 3.6V AA Primary Lithium batteries
    • Additional options for redundancy data retrieval and backup using micro SD card and USB
    • Emergency Battery backup for base station (30 min) for uninterrupted operation using 3.7V AA size Lithium rechargeable batteries
    • Intuitive study set-up and extensive calculations Simplify the validation and reporting process
    • Base Station connections for IRTD and Bath for Sensor Calibration or Verification
    • Protective rubber boot with flexible stand for multiple monitoring configurations
    • Best-in-class data analysis tools, including ability to graph and report in cycles and groups
    • Report tool can process and create merged reports from RF ValProbe, ValProbe or Validator products
    • Versions provide temperature to 0.1°C accuracy, RH to 2% RH, 4/20 mA, 0 to 10 V and dry contact switch inputs, 2-Channel and 5-Channel Temperature logger
    • Up to 3 meter extension cable for RH sensor allows sensor to be placed inside the chamber and logger placed outside
    • Temperature and pressure accuracy meets requirements for ISO-17665, EN554 and EN285 sterilization requirements
    • Easy connection to Kaye Pressure transducer which is designed for harsh environment applications such as steam sterilizers and SIP systems
    • Can be directly connected to 1.5 inch triclover flange via SmartGasket® or similar gasket design
    Environmental
    Body (Logger Enclosure) -40°C to 60°C (Storage)
    0 to 90% RH non-condensing
    -25°C to 60°C (Operating)
    0 to 90% RH non-condensing
    Body (Base Station Enclosure) -40°C to 60°C (Storage)
    0 to 90% RH non-condensing
    0°C to 50°C (Operating)
    0 to 90% RH non-condensing
    External Probe -196°C to 200°C
    Logger Dimensions 110 mm x 65 mm x 30 mm
    (4.3 in x2.6 in x 1.2 in)
    Base Station Dimensions 190 mm x 130 mm x 55 mm
    (7.6 in x 5.2 in x 2.2 in)
    Temperature
    Single/Multi Channel External Sensor • ±0.1°C, range -50°C to +130°C
    • ±0.2°C, range -80°C to -50°C
    • -196°C to -80°C & +130°C to 200°C
    Contact factory for accuracy
    RH • ±2% from 25 to 85%RH
    @ 25°C to 40°C (Non-condensing environment)
    • Certificate states ICH Points
    Auxiliary Inputs • Contact: Dry
    • Voltage and current 0.5% FS
    Battery Life (Varies +10%) 1 min sample rate: 1 Year