- RF Mesh Networking technology provides reliable real time process data. Uses global 2.4 GHz RF frequencies
- Provides 100% data redundancy in both remote logger and base station in addition highly reliable RF network
- New State of Art Industrial design with integrated LCD Display
- Dual powered, logger runs on AC Power and/or Battery. Battery life greater than 1 year in typical use, using Standard 3.6V AA Primary Lithium batteries
- Additional options for redundancy data retrieval and backup using micro SD card and USB
- Emergency Battery backup for base station (30 min) for uninterrupted operation using 3.7V AA size Lithium rechargeable batteries
- Intuitive study set-up and extensive calculations Simplify the validation and reporting process
- Base Station connections for IRTD and Bath for Sensor Calibration or Verification
- Protective rubber boot with flexible stand for multiple monitoring configurations
- Best-in-class data analysis tools, including ability to graph and report in cycles and groups
- Report tool can process and create merged reports from RF ValProbe, ValProbe or Validator products
- Versions provide temperature to 0.1°C accuracy, RH to 2% RH, 4/20 mA, 0 to 10 V and dry contact switch inputs, 2-Channel and 5-Channel Temperature logger
- Up to 3 meter extension cable for RH sensor allows sensor to be placed inside the chamber and logger placed outside
- Temperature and pressure accuracy meets requirements for ISO-17665, EN554 and EN285 sterilization requirements
- Easy connection to Kaye Pressure transducer which is designed for harsh environment applications such as steam sterilizers and SIP systems
- Can be directly connected to 1.5 inch triclover flange via SmartGasket® or similar gasket design
KAYE RF valprobe II Loggers
Tags: kaye, suhu, temperature, thermal, validation system, valprobe.Deskripsi produk:
Feature and specification for Kaye RF valprobe II Loggers:
Environmental | |
Body (Logger Enclosure) | -40°C to 60°C (Storage) 0 to 90% RH non-condensing -25°C to 60°C (Operating) 0 to 90% RH non-condensing |
Body (Base Station Enclosure) | -40°C to 60°C (Storage) 0 to 90% RH non-condensing 0°C to 50°C (Operating) 0 to 90% RH non-condensing |
External Probe | -196°C to 200°C |
Logger Dimensions | 110 mm x 65 mm x 30 mm (4.3 in x2.6 in x 1.2 in) |
Base Station Dimensions | 190 mm x 130 mm x 55 mm (7.6 in x 5.2 in x 2.2 in) |
Temperature | |
Single/Multi Channel External Sensor | • ±0.1°C, range -50°C to +130°C • ±0.2°C, range -80°C to -50°C • -196°C to -80°C & +130°C to 200°C Contact factory for accuracy |
RH | • ±2% from 25 to 85%RH @ 25°C to 40°C (Non-condensing environment) • Certificate states ICH Points |
Auxiliary Inputs | • Contact: Dry • Voltage and current 0.5% FS |
Battery Life (Varies +10%) | 1 min sample rate: 1 Year |